Optionally use the I3s height coordinates
Please make it optional to import and place slpk buildings on the right height on the surface. Now, buildings are always placed on the surface, even if the placement of […]
Show last timeframe for overlays in 2D viewer
By default the 2D viewer shows the first timeframe of grid overlays. Usually the customer is interested in the end result, therefore the last timeframe. When the ;ast timeframe can […]
Export of invalid water constructions in the water configuration wizard.
The ability to make an export (Geojson) of all (Water system) buildings where an error and / or warning is generated. This makes it possible to check them in GIS […]
Timeframes can have custom timestamps
The ability to set your own custom time frames in the Water Overlay. This makes it possible to set a time frame (T=0) at the beginning of your scenario as […]
Priority lane for large calculations during daytime
Please create a priority lane for large calculations during daytime. Sometimes it is needed to do large calculations during daytime instead of during evening hours. Documentation: https://previewsupport.tygron.com/wiki/Calculation_panel#Scheduled_Update_.28long_running.29 https://www.tygron.com/en/idea/text-message-and-or-email-functionality-when-calculation-is-finished/ [embedyt] https://www.youtube.com/watch?v=ukuFiLZyc0c[/embedyt] […]
Extra security on Tygrons own domain with a 2-step authentication
With the 2-step authentication in Tygron’s own domain, the security of the Platform is improved. Please contact us if you are interested in implementing this possibility also in your own […]
More insight in invalid hydraulic structures
‘Invalid’ culverts and other hydraulic structures are now shown at the top of the list of hydraulic structures in the Water Overlay Wizard. More info: https://previewsupport.tygron.com/wiki/Water_Overlay_Wizard
Storage in buildings
In order to improve water storage analysis, please implement an Overlay type BUILDING_LAST_STORAGE, containing the water storage per grid cell, which can be accessed through TQL. More info: https://previewsupport.tygron.com/wiki/Building_last_storage_result_type_(Water_Overlay)
Water level result type
Include water level as a result type in TYGRON and add in a length profile to quickly study backwater effects for river studies. Update: This has been developed. Please check […]
Apply a smaller grid cell size for specific situations
For specific situations, for instance for very narrow waterways that are slanted with the direction of the grid, an even smaller grid size is desired in order to get the […]